Hot-Wand · 13.56 MHz
Current-transformer phase detector
Tip markers use the measured STTC-147 impedances; this slider changes phase only.
Pause to click or drag the grey cursor in the two-cycle scope. At 1×, one cycle takes 8 seconds.
- Instantaneous primary current
- Conducting diodes
- Ring drive / filtered mean
- /
How the napkin model works
Timing, not a circuit solver. RF voltage is sin(θ), primary current is sin(θ + φ), and C33 current is cos(θ). Positive φ means current leads voltage. The voltage trace stays fixed as you adjust φ.
When primary current is negative (right to left), D5 and D6 conduct. C33 current then selects D7 for positive ring drive or D8 for negative ring drive. With forward primary current, D5/D6 are off, D7/D8 are on, and the R10 drive is zero. Red diode fills mean conducting.
The ring is clamped to approximately ±2 V, giving ±20 mA through 100 Ω R10. C34’s purple line is the cycle average: −2 V × φ / 180° over this slider’s ±90° range. This has the same shape as the generator’s current-equivalent plot (divide voltage by 100 Ω). The purple trace is enlarged vertically by 1.5? for visibility; the numeric mean retains its actual value. It has no startup transient or simulated ripple. No buck-loop bias is included.
Cold: 42.3 + j13 Ω; warm: 55 − j16 Ω; hot: 12 + j24 Ω. Preset phase is −atan2(X, R), rounded to whole degrees. These are separate measured states, not a temperature curve.
Based on the current-transformer study and the waveform generator. Renamed: D16/D17/D21/D22 → D5/D6/D7/D8; C47/C75/R40 → C33/C34/R10.